Post Offer Free
WUHAN XIEYUAN AUTOMATION EQUIPMENT CO., LIMITED  

Gold Index: 2953

You are here: home  > Eaton  > Eaton MTL4532-MTL5532 MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 range 1ch pulse isolator

Eaton MTL4532-MTL5532 MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 range 1ch pulse isolator 

Qty (Piece/Pieces) Unit Price (20.0~2000.0 USD)
1 20
1 + 2000
Trade Term: FOB,EXW 
Payment Terms: T/T,L/C,WU,Paypal 
Place of Origin: Hubei, China (Mainland) 
inquire skype
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Means of Transport: Ocean,Land,Air
Packing: Factory Original Packing
Brand Name: Eaton-MTL
Production Capacity: 100 Piece/Pieces Per Week
Delivery Date: In Stock
Product Name: Eaton MTL4532-MTL5532 MTL I...

Pulse Isolator pulse & 4/20mA current outputs

Eaton MTL4532-MTL5532 MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 range 1ch pulse isolator, digital or analogue output

 

Pulse Isolator pulse & 4/20mA current outputs

 

Similar Types : MTL5018AC, MTL5501-SR, MTL5510, MTL5510B, MTL5511, MTL5513, MTL5514, MTL5514D, MTL5516C, MTL5517, MTL5521, MTL5522, MTL5523, MTL5523V-VL, MTL5524, MTL5525, MTL5526, MTL5541, MTL5541A, MTL5541AS, MTL5541S, MTL5544,  MTL5544A, MTL5544AS, MTL5544D, MTL5544S, MTL5546, MTL5546Y, MTL5549, MTL5549Y,  MTL5573, MTL5575, MTL5576-RTD, MTL5576-THC, MTL5581, MTL5582, MTL5582B, MTL5531, MTL5532, MTL5561, MPA5500, MTL5051, MTL5053, MTL5314, MTL5599, PSG60E24RM (replaces MTL5991)

 

The MTLx532 isolates pulses from a switch, proximity detector, current pulse transmitter or voltage pulse transmitter located in a hazardous area. It is ideal for applications involving high pulse rates and fast response times, by repeating the pulses into the safe area. An analogue output proportional to frequency is also provided, together with a relay output, which may be configured to act as an alarm. Configuration is carried out with a personal computer.

 

Number of channels

One, fully floating

 

Sensor type

Switch or proximity detector (NAMUR/BS EN 60947–5–6:2001)

2– or 3–wire voltage or pulse transmitter

 

Location of switch

Zone 0, IIC, T6 hazardous area

Div. 1, Group A, hazardous location

 

Location of proximity detector or transmitter

Zone 0, IIC, T4–T6 if suitably certified

Div.1, Group A, hazardous location

 

Input

Switch input:

Output ON if switch is closed

Proximity detector input:

Excitation: 7.0 to 9.0V dc from 1kΩ nominal

Output ON if input > 2.1mA* (< 2kΩ)

Output OFF if input < 1.2mA* (> 10kΩ)

Switching hysteresis: 0.2mA (650Ω) nominal

*NAMUR and BS EN 60947–5–6:2001standards

Current pulse input:

Transmitter supply: 16.5V dc at 20mA

Short circuit current: 24mA

Output: Iin > 9.0mA = ON, Iin < 7.0mA = OFF

Switching hysteresis: 0.5mA

Voltage pulse input

Input impedance: > 10kΩ

Switching point voltage (Vsp): 3, 6, or 12V nominal

(User selectable by switches on the side of the module)

Output: Vin > Vsp = ON, Vin < Vsp = OFF

Switching hysteresis: 100mV + (0.1 x Vsp) typical

 

Safe-area pulse output

Maximum delay: 10µs

Maximum off–state voltage: 35V

Maximum off–state leakage current: 10µA

Maximum on–state resistance: 25Ω

Maximum on–state current: 50mA

Output OFF if supply fails

Note: LFD signal is Zener-diode protected against inductive loads

 

Safe-area current output

Input capture delay: 2 signal periods (5ms min.)

Signal range: 4 to 20mA

Under/over range: 0 to 22mA

Load resistance: 0 to 450Ω @20mA

Output resistance: >1MΩ

Ripple: < 50µA peak-to-peak

Accuracy: better than 20µA at 20°C

Temperature drift: < 1µA/°C

Risetime (10% - 90%, after step change): 60 ms

 

Alarm output

Relay ON in alarm, 0.5A @ 35Vdc max.

 

Pulse width

High: 10µs min

Low: 10µs min

Frequency range

0 – 50kHz - pulse output mode

0 – 10KHz - for analogue output

 

LED indicators

Green: power indication

Yellow: on when output circuit is on

Red: flashing when line fault or error

 

Power requirement

65mA at 24V dc

70mA at 20V dc

55mA at 35V dc

 

Power dissipation within unit

1.35W maximum at 24V

1.75W maximum at 35V

 

Safety description (Um = 253V rms or dc)

Terminals 2 to 1 and 6 to 1

Uo=10.5V Io=14mA Po=37mW

Terminals 4 to 3 and 1

Uo=28V Io=93mA Po=651mW

Terminals 3 to 1

Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected without further certification into any IS loop with an opencircuit voltage<28V

Terminals 5 to 4 and 1

Vmax ≤ 28V, Imax ≤ 94mA, Pmax ≤ 0.66W

 

Configurator

A personal computer running MTL PCS45 software with a PCL45USB serial interface.

 


 


bigPhoto
skype Ms. Shirley

Tel: 86-151-72506760
Mobile: 151 7250 6760
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

WUHAN XIEYUAN AUTOMATION EQUIPMENT CO., LIMITED [China (Mainland)]


Business Type:Trading Company
City: Wuhan
Province/State: Hubei
Country/Region: China (Mainland)

Shirley:   skype

You May Like:

Product (30)